Hardware pinouts information and cables schemes

Ethernet 10/100/1000 Mbit crossover cable specification users reports and reviews

[Discuss at the forum] [SUBMIT new pinout]

There are 32 approved reports in our database

Date Content
Revision
User opinion Comment Approved by moderator?
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
INCORRECTthe switching of colors is correct, but the wiring is wrong: it should remain alternating half-color, full color.APPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTAPPROVED
CORRECTvery good chart.APPROVED
CORRECTVery good and so helplyAPPROVED
CORRECTAPPROVED
CORRECTThank You!APPROVED
CORRECTCorrectAPPROVED
CORRECTCable work normally. Thanks!!! I use 568BAPPROVED
CORRECTAPPROVED
2008-08-13 14:25:39rev. 2CORRECTAPPROVED
2008-12-26 12:04:25rev. 2CORRECTAPPROVED
2009-02-23 14:32:15rev. 2CORRECTfor Ethernet 100Base and 1000Base tooAPPROVED
2011-09-27 23:43:07rev. 2INCORRECTOne side should be 568A and other side 568B. 1-3,2-6,3-1,4-4,5-5,6-2,7-7,8-8 1 - Orange white 2 - Orange 3 - Green White 4 - Blue 5 - Blue White 6 - Green 7 - Brown white 8 - BrownAPPROVED
2012-11-23 12:12:27rev. 2CORRECTThis is correct and I have tested itAPPROVED
2013-06-07 17:35:38rev. 2ERROR FIXEDНу написали же давным-давно - не кроссируются 4-5 и 7-8 пары (голубая и коричневая)!!! Глупый рисунок, сделанный кем-то по принципу "слышал звон"! И EIA/TIA 568A/B - обозначение не кабелей, а разъёмов! Нет кабеля EIA/TIA 568B! Есть кабель, у которого с одной стороны EIA/TIA 568A, а с другой - EIA/TIA 568B. Это и есть кросс-кабель.APPROVED
2013-08-20 13:31:51rev. 4INCORRECTPicture is still wrong, one side should be A and OTHER IS B.APPROVED
2015-08-09 01:24:19rev. 4INCORRECTgo to one of the many sites that actually show it correctly and copy that!APPROVED
2015-08-17 19:32:20rev. 4INCORRECTThe image is still wrong (as somebody has already mentioned), the "T568B" end is not proper T568B, the blue and brown pairs remain unchanged from the T568A end, only the Orange and green pairs are swapped (Orange with green and white-orange with white-green respectively), this will only work with 10/100Mb connections though Gigabit connections (1000Mb) use T568A/B on one end and a modified B/A (A of other side is B, B of other side is A) with the Blue and brown pairs swapped respectively (blue swapped with brown, white-blue swapped with white-brown) Not only does the image show an improperly labeled modified T568B pinout (doesn't mention it's modified), it also shows improper tip/ring (pos/neg) configuration, while Gigabit connections have integrated Auto-MDIX, the improper tip/ring configuration could cause shorts or hardware damage due to wrong way DC power flow (like installing a battery backwards)APPROVED
2018-05-12 16:46:28rev. 7INCORRECTthe white wires should all be on odd numbered pins for both 568A and 568B. APPROVED
2018-12-07 17:11:06rev. 9INCORRECTAPPROVED
2019-01-10 12:52:19rev. 9ERROR FIXEDhi why are they swapping the blue and brown pair . these pairs are in the same position on both 568a and 568b specs?APPROVED


History of users contributions

Date Content
Revision
Author Comment
2010-08-01 21:29:20rev. 2pasha
2012-02-23 16:25:28rev. 2howyiThe diagram for T-568A and T-568B is confusing and quite weird.

Back to Ethernet 10/100/1000 Mbit crossover cable pinout


Pinouts.ru > Pinout of Ethernet 100Base-T4 crossover cable and layout of 8 pin RJ45 (8P8C) male connector and 8 pin RJ45 (8P8C) male connector
should be correct